Flow Meter Accuracy
± 0.70% of mass flow rate in water using 8800 MultiVariable (MTA option)± 2% of mass flow in steam using 8800 MultiVariable (MTA option)± 1.3% of rate at 30 psia through 2,000 psia in steam using 8800 MultiVariable (MPA option)± 1.2% of rate at 150 psia in steam using 8800 MultiVariable (MCA option)± 1.3% of rate at 300 psia in steam using 8800 MultiVariable (MCA option)± 1.6% of rate at 800 psia in steam using 8800 MultiVariable (MCA option)± 2.5% of rate at 2,000 psia in steam using 8800 MultiVariable (MCA option) ± 0.65% of volumetric rate for liquids (uncompensated)± 1% of volumetric rate for gas and steam (uncompensated)
Output
4-20 mA with HART 5 or 7 (MTA/MPA/MCA option)
4-20 mA with HART 5 or 7 and scalable pulse output (MTA/MPA/MCA option)
FOUNDATION fieldbus ITK6 with 2 Analog Input blocks, 1 Backup Link Active Scheduler function block, 1 Integrator function block, and 1 PID function block(MTA option)
Modbus RS-485 with device status and 4 variables (MTA option)
Wetted Materials
Stainless Steel; 316 / 316L and CF3MNickel Alloy; C-22 and CW2MHigh Temp Carbon Steel; A105 and WCBLow Temp Carbon Steel; LF2 and LCCDuplex; UNS S32760 and 6AConsult factory for other wetted material
Flange Options
ANSI Class 150 to 1500
DIN PN 10 to PN 160
JIS 10K to 40K
Flanges are available in a variety of facings
Consult factory for additional flange ratings
Process Temperature Limits
-330°F to 800°F (-200°C to 427°C)
Temperature Sensor Accuracy
± 2.2°F (1.2°C)
Temperature Sensor Range
-40 to 800°F (-40 to 427°C)